LD8000 MultiGas -Trace N2 and O2 in Ar He Crude Argon

Multigas online gas Analysis solution

he lD8000 MultiGas is an online analyzer to monitor trace n2 and o2 in ar/He/Crude argon. Different
technologies combination is used to achieve the complete solution inside one compact 3u cabinet
Product Catalogue
Category:
Description
Features
Specifications

  • Trace Nitrogen and Oxygen in Argon/Helium/Crude Argon
  • Compact 3U rackmount enclosure
  • Large scale measurement
  • 4-20 mA outputs as standard
  • Range Identification Relay
  • Micro-valve for very low dead volume and fast purging time
  • Low sample consumption
  • Front adjustment valve for sample bypass flow to purge the sample gas line before the analyzer

DETECTOR TYPES
  • Plasma Emission Detector for N2 / Electrochemincal cell for O2
RANGE FOR N2
  • 0 – 1 ppm, resolution to 10 ppb
  • 0 – 10 ppm, resolution to .1 ppm
  • 0 – 100 ppm, resolution to 1 ppm
  • other range possible up to 10000 ppm configurable
RANGE FOR O2
  • 0 – 10 ppm, resolution to 100 ppb
  • 0 – 100 ppm, resolution to .1 ppm
  • 0 – 1000 ppm, resolution to 1 ppm
  • other range possible up to 25% configurable
STANDARD FEATURES
  • Manual or autoranging (user selectable)
  • Microprocessor controlled
  • 5.6” TFT intelligent LCD module with Touch Screen
  • Self diagnosis system with auto-resolve alarm
  • 4-20 mA isolated outputS
  • Alarm Historic
  • Safe calibration procedure to avoid any bad calibration
  • Digital ouputs for remote monitoring: (all dry relay contacts)
    • System status (1 output)
    • Range in use (3 output per impurity)
    • Calibration in use (1 output)
OPTIONS
  • Internal sampling system for zero, span and sample
  • Serial port: RS-232 / 422 / 485 / Profibus
  • 2 alarm outputs (user programmable set point)
GAS CONNECTIONS
  • Sample: 1/8” compression fittings
  • Vent: 1/8” compression fitting
CALIBRATION GAS
  • Zero: LDP1000 purified gas (Getter)
  • Span: 8.0 to 9.5 ppm N2 and 02
SAMPLE FLOW REQUIREMENTS
  • 75 to 200 sccm
RECOMMENDED MAXIMUM OPERATING PRESSURE
  • 30 PSIG (206 kPAG)
RECOMMENDED MINIMUM OPERATING PRESSURE
  • 4 PSIG (28 kPAG) optional 1PSIG (7 kPAG)
OPERATING TEMPERATURE
  • 10 °C to 45 °C
SUPPLY
  • 115 VAC, 50 – 60 Hz or 220 VAC, 50 – 60 Hz
ACCURACY
  • Better than ± 1% full scale
DRIFT
  • < ± 1%
RESPONSE TIME
  • T90 < 10 seconds
O2 SENSOR LIFE
  • 15-21 months (depending O2 concentration level exposition)
WEIGHT
  • 29lbs (13kg)