Power CEMS100 – Emission Monitoring Systems

EFFICIENT SYSTEM FOR CONTINUOUS EMISSION MONITORING IN POWER PLANTS

The PowerCEMS100 power plant analyzer system is the modular solution in the portfolio for customized analyzer systems.

Product Catalogue
Description

PowerCEMS100 meets all relevant standards and legal requirements for continuous emission monitoring systems and is certified according to EN-15267. During the development the top priority is placed on user-friendliness and low maintenance effort. This is reflected in the modular system structure and in the control elements in the analyzer cabinet.

the Power CEMS100 modular analyzer system is an economic and technically perfect solution for extractive measuring tasks. The fully configurable design of the complete system with high quality standard sub-assemblies and components allows the equipment to be customized to provide the ideal solution for prevailing requirements. Retrofitting

At a Glance
At a Glance

  • Cold-extractive analyzer system certified according to EN 15267 and en 14181
  • Plug-and-play analyzer module with 24 V power supplybenefits
  • your investment is secure, as the system can be adapted easily to meet future needs
  • easy commissioning and trouble-free on-site approval of the measuring system by the relevant authoritie
  • Control unit for displaying all measured values and status information on a monitor

    external sensors can be connected via interfaces

    • easy service due to clear separa- tion of the electrical system and the analyzer component

    • easy and quick module replacement for high availability with Can bus technology

    cool dry-extractive

  • Measured values CH4, CO, CO2, NO, NO2, N2O, O2, SO2, other components on request
    Process temperature ≤ +1,000 °C
    Depending on sampling probe
    Sample gas temperature ≤ +200 °C
    Temperature at cabinet inlet
    Conformities Approved for plants requiring approval

    2001/80/EC (13. BImSchV)

    2000/76/EC (17. BImSchV)

    27.BImSchV

    EN 15267

    EN 14181

    Enclosure rating IP 54

    With cooling device: IP 44

    Interfaces RS-485 (option)

    Ethernet TCP/IP

    Bus protocol Modbus TCP

    OPC

    Corrective functions Manual adjustment with test gases

    Automatic testing and adjustment with test gases

    Options NOx-converter

    Cooling device

    Heating

    Bypass pump